Hydrogen sulfide detector transmitter

Hydrogen sulfide detector transmitter has its applications include sewerage plants, laboratories and industrial plants where hydrogen sulfide can happen in high quantities.

Hydrogen sulfide detector transmitter model VAC-E2608-H2S

  1. VAC-E2608-H2S is a long-lasting electrochemical sensor.
  2. Range of measurement for this hydrogen sulfide detector is 0-100 ppm or 0-2000 ppm.
  3. Resolution of measurement for VAC-E2608-H2S is 0.1 ppm or 2 ppm.Hydrogen-Sulfide-Detector-Transmitter-E2608-H2S
  4. It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 Modbus RTU digital interface.
  5. VAC-E2608-H2S has 2 SPST relays.

Specifications of Hydrogen sulfide detector transmitter model VAC-E2608-H2S:

  1. Calibration for VAC-E2608-H2S is Hydrogen Sulfide H2S.
  2. Sensor type used is an electrochemical cell.
  3. The Hydrogen sulfide detector transmitter model VAC-E2608-H2S sampling method is diffusion.
  4. Typical detection range for this hydrogen sulfide detector is 0-100 ppm or 0-2000 ppm.
  5. Maximum overload for 0-100 ppm range is 500 ppm while for 0-2000 ppm range is nd.
  6. Resolution for 0-100 ppm range is 0.1 ppm while for 0-2000 ppm range is 2 ppm.
  7. The response time T90 for 0-100 ppm range is less than 30 seconds while for 0-2000 ppm is less than 25 seconds.
  8. Hydrogen sulfide detector transmitter model VAC-E2608-H2S has 0-1000 output scale.
  9. The operating temperature for 0-100 ppm is -30 to +50 degree Celsius while for 0-2000 ppm is -40 to +50 degree Celsius.
  10. The signal of this hydrogen sulfide detector transmitter is updated every 1 second.
  11. Response time for Hydrogen sulfide detector transmitter model VAC-E2608-H2S is less than 30 seconds.
  12. It has 6 months maintenance interval.
  13. Hydrogen sulfide detector transmitter model VAC-E2608-H2S lifetime is more than 2 years.
  14. Self-diagnostics with full functionality check at start-up.
  15. Warm-up time for VAC-E2608-H2S is less than or equal to 1 minute.
  16. The power supply is 11-30 VDC, 24 VAC or 90-265 VAC.
  17. The power consumption is less than 2 VA.
  18. VAC-E2608-H2S has RS485 Modbus RTU digital interface.
  19. It has 2 analogue outputs settable to 4-20 mA or 0-10 V.
  20. The recommended output scale width of this Hydrogen sulfide detector transmitter is 20-100% of the range with more than 10 × resolution in any case.
  21. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  22. The default warning set-points for 0-100 ppm range at RE1 (LOW) is set at 10; release 8 ppm.
  23. The default warning set-points of this Hydrogen sulfide detector transmitter model for 0-100 ppm range at RE2 (HIGH) is set at 20; release 16 ppm.
  24. The default warning set-points for 0-2000 ppm range is defined by the user within 5-95% of the detection range.
  25. It has a light grey, wall-mounted ABS plastic enclosure and IP65 safety rating.
  26. The dimensions of Hydrogen sulfide detector transmitter model VAC-E2608-H2S is H85 × W82 × D55 millimetres.
  27. It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.
  28. It can be operated at industrial indoor and outdoor locations.
  29. Operating conditions for VAC-E2608-H2S is at 15-90% relative humidity, 0.9-1.1 atmospheric pressure, non-ATEX rated areas.

We supply Hydrogen sulfide detector transmitter across the world covering Europe, USA, Latin America, Asia, Australia, NewZealand, Canada etc.

In the Middle East, we supply Hydrogen sulfide detector transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.
In Africa, we supply Hydrogen sulfide detector transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply Hydrogen sulfide detector transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.