Ethylene oxide gas detector & transmitter

Ethylene oxide gas detector & transmitter are useful in sterilization applications and in the chemical industry. Our Ethylene oxide gas detector with transmitters are having Auxiliary relay contacts to connect to BMS, Alarm system etc.

Ethylene oxide gas detector & transmitter model VAC-E2608-ETO

  1. Ethylene oxide gas detector model VAC-E2608-ETO is a long-lasting electrochemical gas detector.Ethylene-Oxide-Detector-Transmitter-Saudi-Egypt-Iraq-Erbil-Kenya-Nigeria
  2. Ranges of measurement for this ethylene oxide detector is 0-20 or 0-100 ppm.
  3. It has two SPST relays.
  4. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  5. Ethylene oxide gas detector model VAC-E2608-ETO has RS485 Modbus RTU digital interface.

Specifications of Ethylene oxide gas detector & transmitter:

  1. Ethylene oxide gas detector model VAC-E2608-ETO can detect ethylene oxide gas.
  2. Electrochemical is the method of sensing.
  3. The sampling method for the detection of ethylene oxide gas is diffusion.
  4. The typical detection range of this Ethylene oxide gas detector is 0-20 ppm or 0-100 ppm.
  5. Maximum overload for 0-20 ppm detection range is 100 ppm while 200 ppm for 0-100 ppm range.
  6. 0-20 ppm range has 0.1 ppm resolution while 0-100 ppm range has 1 ppm resolution.
  7. The output scale for 0-20 ppm range is 0-200 while for 0-100 ppm range is 0-100.
  8. Response time T90 for 0-20 ppm range is less than 120 seconds while for 0-100 ppm range is less than 140 seconds.
  9. The warning set-points of this Ethylene oxide gas detector for 0-20 ppm range Low is set at 2, release 1.6 ppm while High is set at 5, release 4 ppm.
  10. The warning set-points for 0-100 ppm range is defined by user within 5-95% of the range.
  11. Maintenance interval for VAC-E2608-ETO is 6 months.
  12. Ethylene oxide gas detector model VAC-E2608-ETO sensor lifetime is 2 years.
  13. Self-diagnostics with full functionality check at start-up.
  14. Warm-up time is less than or equal to 1 minute.
  15. The power supply is 11-30 VDC, 24 VAC or 90-265 VAC.
  16. The power consumption of this Ethylene oxide gas detector model is less than 2 VA.
  17. VAC-E2608-ETO has RS485 Modbus RTU digital interface.
  18. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  19. Recommended output scale width is 20-100% of the range with more than 10 x resolution in any case.
  20. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  21. It has a light grey, wall-mounted ABS plastic enclosure and IP65 safety rating.
  22. The dimensions of VAC-E2608-ETO is H85 × W82 × D55 millimetres.
  23. It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.
  24. It can be operated at industrial indoor and outdoor locations.
  25. Operating conditions for Ethylene oxide gas detector model VAC-E2608-ETO is -20 to +50 degree Celsius at 15-95% relative humidity with 0.9-1.1 atmospheric pressure, non-ATEX rated spaces.

NOTE: The detector can be highly sensitive to carbon monoxide, toluene and other organic compounds

We supply Ethylene oxide gas leak detectors and transmitters across the world covering Europe, USA, Latin America, Asia, Australia, NewZealand, Canada etc.

In the Middle East, we supply Ethylene oxide gas leak detectors and transmitters in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.
In Africa, we supply Ethylene oxide gas leak detectors and transmitters in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply Ethylene oxide gas leak detectors and transmitters to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.