Nitric Oxide Detector Transmitter E2648-NO

Nitric oxide detector-transmitter is suitable for applications such as chemical industry, medicine, laboratories and other confined spaces where it is possible to accumulate potentially toxic concentration of nitric oxide.

Nitric Oxide Detector-Transmitter model VAC-E2648-NO:

  1. VAC-E2648-NO is easy to install and has a robust enclosure.
  2. Range of measurement for this nitric oxide detector-transmitter is 0-250 ppm.
  3. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  4. VAC-E2648-NO has RS485 Modbus RTU digital interface.
  5. It has an available relay option.
  6. VAC-E2648-NO has an available remote sensor probe.

Specifications of Nitric oxide detector-transmitter model VAC-E2648-NO:

  1. Calibration of VAC-E2648-NO is Nitric Oxide.
  2. Sensor type used is an electrochemical cell.
  3. The nitric oxide detector-transmitter model VAC-E2648-NO sampling method is diffusion.
  4. The detection range of VAC-E2648-NO is 0-250 ppm.
  5. Resolution for VAC-E2648-NO is 1 ppm.
  6. Maximum overload for this nitric oxide detector-transmitter model VAC-E2648-NO is 1000 ppm.
  7. The signal is updated every 1 second.
  8. Response time is less than 40 seconds.
  9. It has 6 months maintenance interval.
  10. Sensor lifetime of this nitric oxide detector-transmitter model VAC-E2648-NO is more than 2 years.
  11. Self-diagnostics with full functionality check at start-up.
  12. Warm-up time is less than or equal to 1 minute.
  13. The power supply of this nitric oxide detector-transmitter model VAC-E2648-NO is 11-30 VDC or 24 VAC. The power unit of 90-265 VAC is available.
  14. The power consumption is less than 2 VA.
  15. VAC-E2648-NO has RS485 Modbus RTU digital interface.
  16. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  17. It has a die-cast aluminium wall-mounted enclosure with an IP66 safety rating.
  18. The dimensions of this nitric oxide detector-transmitter model VAC-E2648-NO is H120 × W125 × D57 millimetres.
  19. It can be operated at industrial indoor and outdoor areas.
  20. Operating conditions of this nitric oxide detector-transmitter model VAC-E2648-NO is -30 to +50 degrees Celsius at 15-90% relative humidity with 0.9-1.1 atmospheric pressure, non-ATEX rated areas, non-aggressive atmosphere.

NOTE: The sensor may be highly sensitive to hydrogen sulfide and nitrogen dioxide.

Relay outputs (option)

  1. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  2. The default warning set-point of this nitric oxide detector-transmitter model VAC-E2648-NO at LOW is set at 10, release 8 ppm.
  3. The default warning set-point of this nitric oxide detector-transmitter model VAC-E2648-NO at HIGH is set at 25, release 20 ppm.

Other options:

  1. It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.

We supply nitric oxide detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply nitric oxide detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply nitric oxide detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply nitric oxide detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.