Nitric oxide detector-transmitter is suitable for applications such as chemical industry, medicine, laboratories and other confined spaces where it is possible to accumulate potentially toxic concentration of nitric oxide.
Nitric Oxide Detector-Transmitter model VAC-E2648-NO:
- VAC-E2648-NO is easy to install and has a robust enclosure.
- Range of measurement for this nitric oxide detector-transmitter is 0-250 ppm.
- It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
- VAC-E2648-NO has RS485 Modbus RTU digital interface.
- It has an available relay option.
- VAC-E2648-NO has an available remote sensor probe.
Specifications of Nitric oxide detector-transmitter model VAC-E2648-NO:
- Calibration of VAC-E2648-NO is Nitric Oxide.
- Sensor type used is an electrochemical cell.
- The nitric oxide detector-transmitter model VAC-E2648-NO sampling method is diffusion.
- The detection range of VAC-E2648-NO is 0-250 ppm.
- Resolution for VAC-E2648-NO is 1 ppm.
- Maximum overload for this nitric oxide detector-transmitter model VAC-E2648-NO is 1000 ppm.
- The signal is updated every 1 second.
- Response time is less than 40 seconds.
- It has 6 months maintenance interval.
- Sensor lifetime of this nitric oxide detector-transmitter model VAC-E2648-NO is more than 2 years.
- Self-diagnostics with full functionality check at start-up.
- Warm-up time is less than or equal to 1 minute.
- The power supply of this nitric oxide detector-transmitter model VAC-E2648-NO is 11-30 VDC or 24 VAC. The power unit of 90-265 VAC is available.
- The power consumption is less than 2 VA.
- VAC-E2648-NO has RS485 Modbus RTU digital interface.
- It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
- It has a die-cast aluminium wall-mounted enclosure with an IP66 safety rating.
- The dimensions of this nitric oxide detector-transmitter model VAC-E2648-NO is H120 × W125 × D57 millimetres.
- It can be operated at industrial indoor and outdoor areas.
- Operating conditions of this nitric oxide detector-transmitter model VAC-E2648-NO is -30 to +50 degrees Celsius at 15-90% relative humidity with 0.9-1.1 atmospheric pressure, non-ATEX rated areas, non-aggressive atmosphere.
NOTE: The sensor may be highly sensitive to hydrogen sulfide and nitrogen dioxide.
Relay outputs (option)
- It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
- The default warning set-point of this nitric oxide detector-transmitter model VAC-E2648-NO at LOW is set at 10, release 8 ppm.
- The default warning set-point of this nitric oxide detector-transmitter model VAC-E2648-NO at HIGH is set at 25, release 20 ppm.
Other options:
- It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.
We supply nitric oxide detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.
In the Middle East, we supply nitric oxide detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.
In Africa, we supply nitric oxide detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.
Also, we supply nitric oxide detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.