Nitric Oxide Detector Transmitter E2608-NO

Nitric oxide detector transmitter is suitable for applications such as chemical industry, pharmacy, laboratories, and other confined spaces that can generate potentially toxic nitric oxide concentrations.

Nitric oxide detector transmitter model VAC-E2608-NO

  1. VAC-E2608-NO is a long-lasting electrochemical cell.
  2. It has a 0-250 ppm NO detection range.
  3. Resolution of measurement for this nitric oxide detector is 1 ppm.
  4. It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 Modbus RTU digital interface.

Specifications of nitric oxide detector transmitter model VAC-E2608-NO:

  1. Calibration for VAC-E2608-NO is Nitric Oxide NO.
  2. Sensor type used is the electrochemical sensor.
  3. The nitric oxide detector transmitter model VAC-E2608-NO sampling method is diffusion.
  4. Detection range for the nitric oxide detector transmitter model VAC-E2608-NO is 0-250 ppm.
  5. Nitric oxide detector transmitter model VAC-E2608-NO has 1 ppm resolution.
  6. The signal is updated every 1 second.
  7. The response time for VAC-E2608-NO is less than 60 seconds.
  8. It has 6 months maintenance interval.
  9. Nitric oxide detector transmitter model VAC-E2608-NO sensor lifetime is more than 12 months.
  10. Self-diagnostics with full functionality check at start-up.
  11. Warm-up time for nitric oxide detector transmitter model VAC-E2608-NO is less than or equal to 1 minute.
  12. The power supply is 11-30 VDC, 24 VAC or 90-265 VAC.
  13. The power consumption for nitric oxide detector transmitter model VAC-E2608-NO is less than 2 VA.
  14. VAC-E2608-NO has RS485 Modbus RTU digital interface.
  15. It has 2 analogue outputs settable to 4-20 mA or 0-10 V.
  16. The recommended output scale width of this nitric oxide detector transmitter model VAC-E2608-NO is 20-100% of the range with more than 10 × resolution in any case.
  17. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  18. The default warning set-points of this nitric oxide detector transmitter model VAC-E2608-NO at RE1 (LOW) is set at 10; release 8 ppm.
  19. The default warning set-points of this nitric oxide detector transmitter model VAC-E2608-NO at RE2 (HIGH) is set at 25; release 20 ppm.
  20. It has a light grey, wall-mounted ABS plastic enclosure and IP65 safety rating.
  21. The dimensions of nitric oxide detector transmitter model VAC-E2608-NO is H85 × W82 × D55 millimetres.
  22. It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.
  23. It can be operated at industrial indoor and outdoor locations.
  24. Operating conditions for VAC-E2608-NO is -30 to +50 degree Celsius at 15-90% relative humidity, 0.9-1.1 atmospheric pressure, non-ATEX rated areas, non-aggressive atmosphere.

NOTE: The sensor may be sensitive to hydrogen sulfide and nitrogen dioxide.

We supply nitric oxide detector transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply nitric oxide detector transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply nitric oxide detector transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply nitric oxide detector transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.