Flameproof Ethylene Detector Transmitter E2658-C2H4

Flameproof ethylene detector-transmitter is suitable to use in ATEX Zones 2 and 22.

Flameproof Ethylene Detector-Transmitter model VAC-E2658-C2H4:

  1. VAC-E2658-C2H4 is suitable for ATEX Zones 2 and 22.
  2. Ranges of measurement for this flameproof ethylene detector-transmitter are 0-10, 0-200, and 0-1500 ppm.
  3. It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 digital interface.
  4. Two SPST relays are available.

Specifications of Flameproof ethylene detector-transmitter model VAC-E2658-C2H4:

  1. Calibration of VAC-E2658-C2H4 is Ethylene.
  2. Sensor type used is electrochemical.
  3. The flameproof ethylene detector-transmitter model VAC-E2658-C2H4 sampling method is diffusion.
  4. Detection ranges of VAC-E2658-C2H4 are 0-10 ppm (peak 20 ppm), 0-200 pm (peak 500 ppm), and 0-1500 ppm (peak 2000 ppm).
  5. VAC-E2658-C2H4 has 0.1 ppm, 1 ppm, and 5 ppm resolutions.
  6. Flameproof ethylene detector-transmitter model VAC-E2658-C2H4 has less than 2% of signal repeatability.
  7. Response time T80 is less than 60 seconds.
  8. It has 6 months maintenance interval.
  9. Sensor lifetime of this flameproof ethylene detector-transmitter model VAC-E2658-C2H4 is 2 years.
  10. The signal is updated every 1 second.
  11. Self-diagnostics with full functionality check at start-up.
  12. Warm-up time is less than or equal to 1 minute.
  13. The power supply of this flameproof ethylene detector-transmitter model VAC-E2658-C2H4 is 11-30 VDC or 24 VAC. The power supply unit of 24 VAC or with 90-265 VAC is available on request.
  14. The power consumption is less than 2 VA.
  15. VAC-E2658-C2H4 has RS485 Modbus RTU digital interface.
  16. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  17. It has a grey die-cast aluminium enclosure with an IP66 safety rating.
  18. The dimensions of this flameproof ethylene detector-transmitter model VAC-E2658-C2H4 is H120 × W125 × D57 millimetres.
  19. It has flameproof protection, ATEX: II 2 GD, Ex ed IIC T4 Gb.
  20. VAC-E2658-C2H4 cable gland is M25 for SWA cable or steel conduit Ø10-17 millimetres.
  21. Flameproof ethylene detector-transmitter model VAC-E2658-C2H4 has 0.5-1.5 square millimetres wire conductors.
  22. It can be operated at industrial indoor and outdoor areas, safe areas and ATEX Zones 2 and 22.
  23. Operating conditions of this flameproof ethylene detector-transmitter model VAC-E2658-C2H4 is less than 95% relative humidity with 1 atmospheric pressure ±10%. Corrosive gases should be avoided.

Relay option (ordering code R)

  1. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  2. The default warning set-point of this flameproof ethylene detector-transmitter model VAC-E2658-C2H4 within 5-95% of the detection range is determined by the user.

Other options: 

  1. Flameproof ethylene detector-transmitter model VAC-E2658-C2H4 humidity compensation is up to 100% relative humidity.

We supply flameproof ethylene detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply flameproof ethylene detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply flameproof ethylene detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply flameproof ethylene detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.