E2660-CO-CO2 Dual Gas Transmitter

The CO-CO2 transmitter can be used for simultaneous monitoring of carbon monoxide and carbon dioxide concentration. This detector-transmitter is an ideal for underground parking and other confined spaces, where it is possible to accumulate potentially toxic concentrations of carbon monoxide and carbon dioxide.

Dual Gas-Transmitter model VAC-E2660-CO-CO2:

  1. VAC-E2660-CO-CO2 can be monitored CO and CO2 simultaneously.
  2. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  3. VAC-E2660-CO-CO2 has a digital interface for RS485 connections working on Modbus RTU protocol.
  4. It has a wall-mount IP65 protected housing.

Specifications of Dual Gas-transmitter model VAC-E2660-CO-CO2:

  1. VAC-E2660-CO-CO2 can detect Carbon Monoxide CO and Carbon Dioxide CO2.
  2. The CO sensor type used is a long-life electrochemical cell. The CO2 sensor type used is an optical (NDIR) sensor.
  3. The dual gas transmitter model VAC-E2660-CO-CO2 sampling method is diffusion.
  4. The detection range for this dual gas transmitter model VAC-E2660-CO-CO2 is 0 to 300 ppm CO and 0 to 10 000 ppm CO2. Other ranges on request.
  5. The signal is updated every 1 second.
  6. Response time is less than or equal to 30 s for CO and ca. 2-3 minutes for CO2. 
  7. The recommended maintenance interval of CO sensor is 6 months and CO2 sensor is maintenance free.
  8. The sensor lifetime of CO sensor is more than 6 years and it is replaceable. The sensor lifetime of CO2 sensor is more than 10 years and it is non-replaceable.
  9. Self-diagnostics with full functionality check at start-up.
  10. Warm-up time of this dual gas transmitter model VAC-E2660-CO-CO2 is less than or equal to 10 minutes.
  11. The power supply of this dual gas transmitter model VAC-E2660-CO-CO2 is 11 to 30 VDC, 24 VAC or 90 to 265 VAC.
  12. The power consumption is less than 2 VA.
  13. VAC-E2660-CO-CO2 has a digital interface for RS485 connections working on Modbus RTU protocol.
  14. It has a universal 2 analogue outputs settable at 4-20 mA or 0-10 V.
  15. The recommended output scale width is 20-100% of the range (for CO down to 5-100% allowed); with more than 10 times resolution in any case. 
  16. It has a grey ABS plastic, wall mount, IP65 enclosure.
  17. The dimensions of this dual gas transmitter model VAC-E2660-CO-CO2 is H90 × W145× D55 mm.
  18. It has M25 sensor heads. 
  19. VAC-E2660-CO-CO2 has an IP65 secured remote sensor probe, shielded cable. The default length of the cable is 3.0 meters.
  1. Operating conditions of this dual gas transmitter model VAC-E2660-CO-CO2 is -20 to +50 °C, 15 to 90 %RH non condensing* pressure 0.9 to 1.1 atm.

We supply dual gas transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply dual gas transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply dual gas transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply dual gas transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.