Solvent Vapor Detector Transmitter E2611-VOC

Solvent vapour detector-transmitter is suitable for applications such as storages, painting chambers, and other confined spaces where it is possible to accumulate toxically or potentially explosive concentration of volatile organic compounds.

Solvent Vapour Detector-Transmitter model VAC-E2611-VOC

  1. VAC-E2611-VOC is a long-lasting metal-oxide gas detector.
  2. Range of measurement for this solvent vapour detector-transmitter is 0-100% LEL or 0-100 to 0-1000 ppm.
  3. It has an acoustic alarm with two SPST relays.
  4. It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 digital interface.

Specifications of Solvent vapour detector-transmitter model VAC-E2611-VOC:

  1. VAC-E2611-VOC target gases are toluene, xylene, and ethanol.
  2. The default calibration for VAC-E2611-VOC is toluene.
  3. The sensing method used is a long-life metal-oxide gas detector.
  4. The solvent vapour detector-transmitter model VAC-E2611-VOC sampling method is diffusion.
  5. Detection range options are 0-100 to 0-1000 ppm or 0-100% LEL.
  6. The resolution of this solvent vapour detector-transmitter model VAC-E2611-VOC is 3 ppm toluene.
  7. The signal is updated every 1 second.
  8. Response time is less than 120 seconds.
  9. It has 12 months maintenance interval.
  10. The sensor lifetime of this solvent vapour detector-transmitter model VAC-E2611-VOC is more than 5 years.
  11. Self-diagnostics with full functionality check at start-up.
  12. Warm-up time is less than or equal to 1 minute.
  13. The power supply of this solvent vapour detector-transmitter model VAC-E2611-VOC is 11-30 VDC or 90-265 VAC.
  14. The power consumption is less than 2 VA.
  15. Solvent vapour detector-transmitter model VAC-E2611-VOC has RS485, Modbus RTU protocol digital interface.
  16. VAC-E2611-VOC has 85 dB buzzer alarm.
  17. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  18. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  19. The default alarm set-points of this solvent vapour detector-transmitter model VAC-E2611-VOC with 0-500 ppm range at Low is set at 100, release 80 ppm.
  20. The default alarm set-points of this solvent vapour detector-transmitter model VAC-E2611-VOC with 0-500 ppm range at High is set at 300, release 240 ppm.
  21. The default alarm set-points of this solvent vapour detector-transmitter model VAC-E2611-VOC at Low is set at 20, release 16% LEL.
  22. The default alarm set-points of this solvent vapour detector-transmitter model VAC-E2611-VOC at High is set at 50, release 40% LEL.
  23. It has a wall-mounted ABS plastic enclosure with ventilation slots and an IP20 safety rating.
  24. The dimensions of this solvent vapour detector-transmitter model VAC-E2611-VOC is H85 × W85 × D37 millimetres.
  25. It can be operated at residential, business, and industrial indoor spaces.
  26. Operating conditions of this solvent vapour detector-transmitter model VAC-E2611-VOC is -30 to +70 degrees Celsius at less than 95% relative humidity, without condensation, non-ATEX rated areas, non-aggressive atmosphere. 

We supply solvent vapour detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we solvent vapour detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply solvent vapour detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply solvent vapour detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.