Nitrogen Dioxide Detector Transmitter E2608-NO2

Nitrogen dioxide detector transmitter is suitable for applications such as underground parking, kitchens, boiler rooms, and other confined spaces where potentially toxic levels of nitrogen dioxide can build up.

Nitrogen dioxide detector transmitter model VAC-E2608-NO2

  1. VAC-E2608-NO2 is a long-lasting electrochemical cell.
  2. It has 0-20 ppm or 0-200 ppm detection range.
  3. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  4. VAC-E2608-NO2 has RS485 Modbus RTU digital interface.
  5. It has 2 SPST relays.
  6. There is a remote probe available.

Specifications of nitrogen dioxide detector transmitter model VAC-E2608-NO2:

  1. Calibration for VAC-E2608-NO2 is Nitrogen Dioxide NO2.
  2. Sensor type used is the electrochemical sensor.
  3. The nitrogen dioxide detector transmitter model VAC-E2608-NO2 sampling method is diffusion.
  4. Typical detection range for this nitrogen dioxide detector is 0-20 ppm or 0-200 ppm.
  5. Maximum overload for 0-20 ppm range is 100 ppm while for 0-200 ppm is 1000 ppm.
  6. 0-20 ppm range has 0.1 ppm resolution while 0-200 ppm range has 1 ppm resolution.
  7. The response time for 0-20 ppm range is less than 60 seconds while for 0-200 ppm range is less than 40 seconds.
  8. Operating conditions for 0-20 ppm range is -30 to +50 degree Celsius while for 0-200 ppm is -20 to +50 degree Celsius at 15-90% relative humidity with 1.1 atmospheric pressure, non-ATEX rated areas, non-aggressive environment. NOTE: The sensor may be highly sensitive to Cl2 (as well as H2S, SO2, O3 for a maximum of 0 … 200 ppm).
  9. The signal is updated every 1 second.
  10. It has 6 months maintenance interval.
  11. Nitrogen dioxide detector transmitter model VAC-E2608-NO2 sensor lifetime is more than 2 years.
  12. Self-diagnostics with full functionality check at start-up.
  13. Warm-up time is less than or equal to 1 minute.
  14. The power supply of nitrogen dioxide detector transmitter model VAC-E2608-NO2 is 11-30 VDC, 24 VAC or 90-265 VAC.
  15. Nitrogen dioxide detector transmitter model VAC-E2608-NO2 power consumption is less than 2 VA.
  16. VAC-E2608-NO2 has RS485 Modbus RTU digital interface.
  17. It has 2 analogue outputs settable to 4-20 mA or 0-10 V.
  18. The recommended output scale width of this nitrogen dioxide detector transmitter model VAC-E2608-NO2 is 20-100% of the range with more than 10 × resolution in any case.
  19. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  20. The warning set-points for this nitrogen dioxide detector transmitter model VAC-E2608-NO2 at RE1 (LOW) is set at 3; release 2.4 ppm.
  21. The warning set-points for this nitrogen dioxide detector transmitter model VAC-E2608-NO2 at RE2 (HIGH) is set at 6; release 4 ppm.
  22. The warning set-point for 0-200 ppm is set by the user within 5-95% of the range.
  23. It has a light grey, wall-mounted ABS plastic enclosure with an IP65 safety rating.
  24. The dimensions of this nitrogen dioxide detector transmitter model VAC-E2608-NO2 is H85 × W82 × D55 millimetres.
  25. It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.
  26. It can be operated at indoor and outdoor locations.

We supply nitrogen dioxide detector transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply nitrogen dioxide detector transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply nitrogen dioxide detector transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply the nitrogen dioxide detector transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.