Hydrogen Sulfide Transmitter E2618-H2S

Hydrogen sulfide transmitter is suitable for applications such as sewerage systems, labs, industrial premises and other confined spaces where it is possible to accumulate potentially toxic concentration of hydrogen sulfide.

Hydrogen Sulfide Transmitter model VAC-E2618-H2S:

  1. VAC-E2618-H2S is a long-lasting electrochemical cell.
  2. Ranges of measurement for this hydrogen sulfide transmitter are 0-100 ppm and 0-2000 ppm.
  3. Resolutions of measurement for VAC-E2618-H2S are 0.1 and 2 ppm.
  4. VAC-E2618-H2S provides either fixed or remote sensor probe.
  5. It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 digital interface.

Specifications of Hydrogen sulfide transmitter model VAC-E2618-H2S:

  1. Calibration of VAC-E2618-H2S is Hydrogen Sulfide.
  2. Sensor type used is an electrochemical cell.
  3. The hydrogen sulfide transmitter model VAC-E2618-H2S sampling method is diffusion.
  4. Typical detection ranges of VAC-E2618-H2S are 0-100 ppm and 0-2000 ppm.
  5. Maximum overload for this hydrogen sulfide transmitter model VAC-E2618-H2S with 0-100 ppm range is 500 ppm while for 0-2000 ppm range is nd.
  6. The resolution of this hydrogen sulfide transmitter model VAC-E2618-H2S with 0-100 ppm range is 0.1 ppm while for 0-2000 ppm range is 2 ppm.
  7. Response time T90 for 0-100 ppm range is less than 30 seconds while for 0-2000 ppm range is less than 25 seconds.
  8. The output scale of this hydrogen sulfide transmitter model VAC-E2618-H2S is 0-1000.
  9. Operating temperature for VAC-E2618-H2S with 0-100 ppm range is -30 to +50 degrees Celsius while for 0-2000 ppm range is -40 to +50 degrees Celsius.
  10. The signal is updated every 1 second.
  11. It has 12 months maintenance interval.
  12. Sensor lifetime of this hydrogen sulfide transmitter model VAC-E2618-H2S is more than 2 years.
  13. Self-diagnostics with full functionality check at start-up.
  14. Warm-up time is less than or equal to 1 minute.
  15. The power supply of this hydrogen sulfide transmitter model VAC-E2618-H2S is 11-30 VDC or 24 VAC.
  16. The power consumption is less than 2 VA.
  17. VAC-E2618-H2S has RS485 Modbus RTU digital interface.
  18. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  19. It has a light grey ABS plastic enclosure with an IP65 safety rating.
  20. The dimensions of this hydrogen sulfide transmitter model VAC-E2618-H2S is H82 × W80 × D55 millimetres.
  21. It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 metres.
  22. It can be operated at industrial indoor and outdoor areas.
  23. Operating conditions of this hydrogen sulfide transmitter model VAC-E2618-H2S is 15-90% relative humidity with atmospheric pressure ±10%, non-ATEX rated areas.

LCD indicator option

  1. Operating temperature of the LCD indicator is 0 to +50 degrees Celsius.
  2. The display dimensions of this hydrogen sulfide transmitter model VAC-E2618-H2S LCD indicator is 72 × 36 millimetres.
  3. VAC-E2618-H2S LCD indicator has 3.5 7-segment number of digits.
  4. The character height in the LCD indicator is 14 millimetres.
  5. Hydrogen sulfide transmitter model VAC-E2618-H2S LCD indicator has a backlight feature.

We supply hydrogen sulfide transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply hydrogen sulfide transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply hydrogen sulfide transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply hydrogen sulfide transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.