Fluorescence-based oxygen detector-transmitter is used to monitor the absence of oxygen in gas mixtures for specific purposes as well as to avoid a crucial drop in O2 concentration.
Fluorescence-based Oxygen Detector-Transmitter model VAC-E2608-O2-L
- VAC-E2608-O2-L is a long-lasting optical sensor.
- Range of measurement for this fluorescence-based oxygen detector-transmitter is 0-25% vol O2.
- Resolution of measurement of VAC-E2608-O2-L is 0.01% vol O2.
- Default alarm set-points is 19.5 or 18.0% vol O2.
- It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 Modbus RTU digital interface.
Specifications of Fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L:
- Calibration for VAC-E2608-O2-L is Oxygen O2.
- Sensing method used is Optical (fluorescence-based).
- The fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L sampling method is diffusion.
- Detection range for this fluorescence-based oxygen detector-transmitter is 0-25% vol O2.
- Resolution range of VAC-E2608-O2-L is 0.01% vol O2.
- It has an accuracy of less than 2% FS.
- The signal is updated every 1 second.
- Response time is less than 30 seconds.
- VAC-E2608-O2-L is a maintenance free sensor.
- VAC-E2608-O2-L sensor lifetime is more than 5 years.
- Self-diagnostics with full functionality check at start-up.
- Warm-up time for VAC-E2608-O2-L is less than or equal to 1 minute.
- The power supply of this fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L is 11-30 VDC, 24 VAC or 90-265 VAC.
- The power consumption is less than 2 VA.
- VAC-E2608-O2-L has RS485 Modbus RTU digital interface.
- It has 2 analogue outputs settable to 4-20 mA or 0-10 V.
- The recommended output scale width is 20-100% of the range with more than 10 × resolution in any case.
- It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
- The default warning set-points of this fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L at RE1 (High) is set at 19.5%, release 20.5%.
- The default warning set-points of this fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L at RE2 (Low) is set at 18%, release 19%.
- It has a light grey, wall-mounted ABS plastic with an IP65 safety rating.
- The dimensions of this fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L is H85 × W82 × D55 millimetres.
- It has an IP65 secured remote sensor probe, shielded cable. The cable’s default length is 3.0 meters.
- It can be operated at industrial indoor and outdoor locations.
- Operating conditions of this fluorescence-based oxygen detector-transmitter model VAC-E2608-O2-L is -30 to 60 degree Celsius at 15-90% relative humidity, with 0.9-1.1 atmospheric pressure, non-ATEX rated areas, non-aggressive atmosphere.
*if no thermal fluctuations occur
We supply fluorescence-based oxygen detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.
In the Middle East, we supply fluorescence-based oxygen detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.
In Africa, we supply fluorescence-based oxygen detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.
Also, we supply fluorescence-based oxygen detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.