Flameproof Chlorine Detector Transmitter E2658-CL2

Flameproof chlorine detector-transmitter is suitable to use in ATEX Zones 2 and 22.

Flameproof Chlorine Detector-Transmitter model VAC-E2658-CL2:

  1. VAC-E2658-CL2 is suitable for ATEX Zones 2 and 22.
  2. Range of measurement for this flameproof chlorine detector-transmitter is 0-10 ppm.
  3. Resolution of measurement of VAC-E2658-CL2 is 0.1 ppm.
  4. It has 2 analogue outputs settable at 4-20 mA or 0-10 V with RS485 digital interface.
  5. Two SPST relays are available.

Specifications of Flameproof chlorine detector-transmitter model VAC-E2658-CL2:

  1. Calibration of VAC-E2658-CL2 is Chlorine.
  2. Sensor type used is an electrochemical cell.
  3. The flameproof chlorine detector-transmitter model VAC-E2658-CL2 sampling method is diffusion.
  4. Typical detection range is 0-10 ppm.
  5. Maximum overload for this flameproof chlorine detector-transmitter model VAC-E2658-CL2 is 100 ppm.
  6. VAC-E2658-CL2 has 0.1 ppm resolution.
  7. The signal is updated every 1 second.
  8. Response time T90 is less than 60 seconds.
  9. It has 6 months maintenance interval.
  10. Sensor lifetime of this flameproof chlorine detector-transmitter model VAC-E2658-CL2 is more than 2 years.
  11. Self-diagnostics with full functionality check at start-up.
  12. Warm-up time is less than or equal to 1 minute.
  13. The power supply of this flameproof chlorine detector-transmitter model VAC-E2658-CL2 is 11-30 VDC or 24 VAC. The power unit of 90-265 VAC is also available.
  14. The power consumption is less than 2 VA.
  15. VAC-E2658-CL2 has RS485 Modbus RTU digital interface.
  16. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  17. It has a grey die-cast aluminium enclosure with an IP66 safety rating.
  18. The dimensions of this flameproof chlorine detector-transmitter model VAC-E2658-CL2 is H120 × W125 × D57 millimetres.
  19. It has flameproof protection, ATEX: II 2 GD, Ex ed IIC T4 Gb.
  20. VAC-E2658-CL2 cable gland is M25 for SWA cable or steel conduit Ø10-17 millimetres.
  21. Flameproof chlorine detector-transmitter model VAC-E2658-CL2 has 0.5-1.5 square millimetres wire conductors.
  22. It can be operated at industrial indoor and outdoor areas, safe areas and ATEX Zones 2 and 22.
  23. Operating conditions of this flameproof chlorine detector-transmitter model VAC-E2658-CL2 is -20 to +50 degrees Celsius at 15-95% relative humidity with 1 atmospheric pressure ±10%.
  24. It has 2 SPST output relays (closing contact) with 250 VAC or 30 VDC at 5 A max current.
  25. The default warning set-point of this flameproof chlorine detector-transmitter model VAC-E2658-CL2 at LOW is set at 0.5 ppm, release 0.4 ppm.
  26. The default warning set-point of this flameproof chlorine detector-transmitter model VAC-E2658-CL2 at HIGH is set at 1 ppm, release 0.8 ppm.

NOTE: The sensor may be highly sensitive to hydrogen sulfide.

We supply flameproof chlorine detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply flameproof chlorine detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply flameproof chlorine detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply flameproof chlorine detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.