E2648-CO2-10K Carbon Dioxide Detector Transmitter

Carbon dioxide detector-transmitter is suitable for applications such as HVAC and air quality control in public, office and industrial buildings, greenhouses, underground parking, boiler houses, and other areas, where it is possible to accumulate potentially toxic concentration of carbon dioxide. This detector is a multifunctional measurement instrument.

Carbon Dioxide Detector-Transmitter model VAC-E2648-CO2-10K:

  1. VAC-E2648-CO2-10K is a stable long-life optical NDIR gas sensor.
  2. The range of measurement for this carbon dioxide detector-transmitter is 0 to 10 000 ppm CO2.
  3. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  4. VAC-E2648-CO2-10K has a digital interface for RS485 connections working on Modbus RTU protocol.
  5. It has a relay option and remote probe option.

Specifications of Carbon Dioxide detector-transmitter model VAC-E2648-CO2-10K:

  1. VAC-E2648-CO2-10K can detect Carbon Dioxide CO2.
  2. Sensor type used is NDIR.
  3. The carbon dioxide detector-transmitter model VAC-E2648-CO2-10K sampling method is diffusion.
  4. The detection range for this carbon dioxide detector-transmitter model VAC-E2648-CO2-10K is 0 to 10 000 ppm CO2.
  5. VAC-E2648-CO2-10K has 1 ppm resolution.
  6. The accuracy of this carbon dioxide detector-transmitter model VAC-E2648-CO2-10K is ± (50 ppm + 3% of reading) in the range 300 to 5000 ppm.
  7. The signal is updated every 2 seconds.
  8. Response time T90 is ~2 minutes. 
  9. It has up to 5 years of calibration interval.
  10. The sensor lifetime of this carbon dioxide detector-transmitter model VAC-E2648-CO2-10K is ca. 10 years.
  11. Self-diagnostics with full functionality check at start-up.
  12. Warm-up time is less than or equal to 1 minute.
  13. The power supply of this carbon dioxide detector-transmitter model VAC-E2648-CO2-10K is 11 to 30 VDC / 24 VAC. Option: 90 to 265 VAC power unit.
  14. The power consumption is less than 2 VA.
  15. VAC-E2648-CO2-10K has a digital interface for RS485 connections working on Modbus RTU protocol.
  16. It has 2 analogue outputs settable at 4-20 mA or 0-10 V.
  17. It has a die-cast aluminium, wall mount, IP66 enclosure.
  18. The dimensions of this carbon dioxide detector-transmitter model VAC-E2648-CO2-10K is H120 × W125 × D57 mm.
  19. VAC-E2648-CO2-10K can be operated at industrial indoor and outdoor areas.
  20. Operating conditions of this carbon dioxide detector-transmitter model VAC-E2648-CO2-10K is -0 to +50 °C, 0 to 95 %RH, pressure 0.9 to 1.1 atm; non ATEX rated areas and non-aggressive atmosphere.
  21. It has 2 SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max as an option. And the default alarm set points are to be determined by the user within 5-95% of the detection range.
  22. Carbon dioxide detector-transmitter model VAC-E2648-CO2-10K has 0.5 to 2 bar absolute pressure compensation as an option.
  23. It has an IP65 secured remote sensor probe, shielded cable as an option. The default length of this cable is 3.0 meters.

We supply carbon dioxide detector-transmitter across the world covering Europe, USA, Latin America, Asia, Australia, New Zealand, Canada etc.

In the Middle East, we supply carbon dioxide detector-transmitter in the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia etc.

In Africa, we supply carbon dioxide detector-transmitter in countries including Kenya, Algeria, Tanzania, Djibouti, Chad, Ghana, Rwanda, Uganda, Nigeria, Ethiopia, Morocco, Angola, South Africa etc.

Also, we supply carbon dioxide detector-transmitter to India, Bangladesh, Pakistan, Afghanistan, Kazakhstan, Srilanka, Maldives and Cyprus.